JUAL IFM ecomat300 AirBoxes for pneumatic applications

AS-Interface systems and sensors - AirBoxes for pneumatic applications

  • Very safe mounting and high protection rating
  • Slide valves free from overlapping
  • High pressure peak resistance up to 12 bar
  • Three freely selectable directions of the flat cable
  • Extended addressing mode
 
AC2024 AirBox 2DI 2PO M12 AS-i AirBox, 2 digital inputs, IP 65, Ambient temperature 0...55 °C, contact pins on FC or SC lower module
AC2027 AirBox 2DI 2PO M12 AS-i AirBox, Connection to the pneumatic system by tube fittings, 2 digital inputs, IP 67, Ambient temperature 0...55 °C, contact pins on FC or SC lower module
AC2041 AirBox 2x2DI 2PO M12 AS-i AirBox, Connection to the pneumatic system by tube fittings, 2 x 2 digital inputs, IP 65, Ambient temperature 0...55 °C, contact pins on FC-E or SC lower module
AC2042 AirBox 2x2DI 2PO M12 AS-i AirBox, Connection to the pneumatic system by tube fittings, 2 x 2 digital inputs, IP 65, Ambient temperature 0...55 °C, contact pins on FC or SC lower module
AC2046 AirBox 2DI 1PO M12 AS-i AirBox, Connection to the pneumatic system by tube fittings, 1 x 2 or 2 x 1 digital inputs, IP 65, Ambient temperature 0...55 °C, contact pins on FC or SC lower module
AC2048 AirBox 2DI 1PO M12 AS-i AirBox, Connection to the pneumatic system by tube fittings, IP 65, Ambient temperature 0...55 °C, contact pins on FC-E or SC lower module
AC2055 AirBox 2x2DI 2PO M12 V2A AS-i AirBox, Connection to the pneumatic system by tube fittings, Manual override by pressing/releasing or pressing/turning/locking, 2 x 2 digital inputs, IP 67, Ambient temperature 0...55 °C, contact pins on FC or SC lower module
AC2057 Airbox 2DI 1PO M12 V2A AS-i AirBox, Connection to the pneumatic system by tube fittings, 1 x 2 or 2 x 1 digital inputs, IP 67, Ambient temperature 0...55 °C, contact pins on FC or SC lower module
AC246A AirBox 5/2 2DI-Y II 3D AS-i AirBox, 5/2-way slide valve free from overlapping, monostable, Three orientations of the flat cable are possible, AS-i flat cable connection, IP 50, Ambient temperature -10...50 °C
AC5227 AirBox 2x3/2 2DI IP67 AS-i AirBox, 2 x 3/2-way slide valves free from overlapping, monostable, Three orientations of the flat cable are possible, AS-i flat cable connection, IP 67, Ambient temperature -10...55 °C
AC5228 AirBox 2x3/2 4DI-Y IP67 AS-i AirBox, 2 x 3/2-way slide valves free from overlapping, monostable, Three orientations of the flat cable are possible, AS-i flat cable connection, IP 65 / IP 67, Ambient temperature -10...55 °C
AC5243 AirBox 2x3/2 4DI-Y IP67 AUX AS-i AirBox, 2 x 3/2-way slide valves free from overlapping, monostable, Three orientations of the flat cable are possible, AS-i flat cable connection, IP 65 / IP 67, Ambient temperature -10...55 °C
AC5246 AirBox 5/2 4DI-Y IP67 AS-i AirBox, 5/2-way slide valve free from overlapping, monostable, Three orientations of the flat cable are possible, AS-i flat cable connection, IP 65 / IP 67, Ambient temperature -10...55 °C
AC5249 AirBox 5/2 4DI-Y IP67 AUX AS-i AirBox, 5/2-way slide valve free from overlapping, monostable, Three orientations of the flat cable are possible, AS-i flat cable connection, IP 65 / IP 67, Ambient temperature -10...55 °C
AC5250 AirBox 5/2 bist. 2DI-Y IP67 AS-i AirBox, 5/2-way bistable slide valve free from overlapping, Three orientations of the flat cable are possible, AS-i flat cable connection, Addressing socket, IP 65 / IP 67, Ambient temperature -10...55 °C
AC5251 AirBox 5/2 bistable 4DI-Y IP67 AS-i AirBox, 5/2-way bistable slide valve free from overlapping, Three orientations of the flat cable are possible, AS-i flat cable connection, Version 2.11 and 3.0 with extended addressing mode, IP 65 / IP 67, Ambient temperature -10...55 °C
AC5253 AirBox 5/2 bistable 4DI-Y AUX AS-i AirBox, 5/2-way bistable slide valve free from overlapping, Three orientations of the flat cable are possible, AS-i flat cable connection, Version 2.11 and 3.0 with extended addressing mode, IP 65 / IP 67, Ambient temperature -10...55 °C
AC5270 AirBox 5/3 closed 4DI-Y IP67 AS-i AirBox, 5/3-way slide valve free from overlapping, closed, Three orientations of the flat cable are possible, AS-i flat cable connection, IP 65 / IP 67, Ambient temperature -10...55 °C
AC5271 AirBox 5/3 closed 4DI-Y AUX AS-i AirBox, 5/3-way slide valve free from overlapping, closed, Three orientations of the flat cable are possible, AS-i flat cable connection, IP 65 / IP 67, Ambient temperature -10...55 °C
AC5285 AirBox 2x3/2 2x2DI IP67 AS-i AirBox, 2 x 3/2-way slide valves free from overlapping, monostable, Three orientations of the flat cable are possible, AS-i flat cable connection, IP 65 / IP 67, Ambient temperature -10...55 °C
AC5287 AirBox 5/2 2DI-Y IP67 AS-i AirBox, 5/2-way slide valve free from overlapping, monostable, Three orientations of the flat cable are possible, AS-i flat cable connection, IP 65 / IP 67, Ambient temperature -10...55 °C
AC528A AirBox 2x3/2 4DI-Y II 3D AS-i AirBox, 2 x 3/2-way slide valves free from overlapping, Three orientations of the flat cable are possible, AS-i flat cable connection, Version 2.11 and 3.0 with extended addressing mode, IP 50, Ambient temperature -10...50 °C
AC542A AirBox 2x3/2 4DI-Y II 3D AS-i AirBox, 2 x 3/2-way slide valves free from overlapping, monostable, Three orientations of the flat cable are possible, AS-i flat cable connection, Digital inputs, Addressing socket, AS-i profile S-7.F.F, Versions 2.11 and 3.0, ATEX approval, Group II, category 3D, only in conjunction with impact protection housing E7000A or equivalent protection
AC546A AirBox 5/2 4DI-Y II 3D AS-i AirBox, 5/2-way slide valve free from overlapping, monostable, Three orientations of the flat cable are possible, AS-i flat cable connection, Version 2.11 and 3.0 with extended addressing mode, Addressing socket, ATEX approval, Group II, category 3D, only in conjunction with impact protection housing E7000A or equivalent protection
AC551A AirBox 5/2 bist. 4DI-Y II 3D AS-i AirBox, 5/2-way bistable slide valve free from overlapping, Three orientations of the flat cable are possible, AS-i flat cable connection, Version 2.11 and 3.0 with extended addressing mode, Addressing socket, ATEX approval, Group II, category 3D, only in conjunction with impact protection housing E7000A or equivalent protection
AC570A AirBox 5/3 closed 4DI-Y II 3D AS-i AirBox, 5/3-way slide valve free from overlapping, closed, Three orientations of the flat cable are possible, AS-i flat cable connection, Version 2.11 and 3.0 with extended addressing mode, Addressing socket, ATEX approval, Group II, category 3D, only in conjunction with impact protection housing E7000A or equivalent protection

JUAL IFM efector100 Inductive sensors - Area sensors with long sensing range