IO-Link masters
- For connection of up to eight IO-Link devices
- Reliable transmission of machine data, process parameters and diagnostic data to the controller
- Simultaneous data exchange with the controller and the IT world
- Units for field applications and control cabinets
- With integrated fieldbus interface
| AL1000 | IO-Link Master PL PN 8P IP67 | IO-Link master with Profinet interface, max. 8 IO-Link ports / max. 12 digital inputs / max. 8 digital outputs, IP 65 / IP 67, Ambient temperature -25...60 °C |
| AL1010 | IO-Link Master PL PB 8P IP67 | IO-Link master with Profibus interface, max. 8 IO-Link ports / max. 12 digital inputs / max. 8 digital outputs, IP 65 / IP 67, Ambient temperature -25...60 °C |
| AL1020 | IO-Link Master PL EIP 8P IP67 | IO-Link master with EtherNet/IP interface, max. 8 IO-Link ports / max. 12 digital inputs / max. 8 digital outputs, IP 65 / IP 67, Ambient temperature -25...60 °C |
| AL1030 | IO-Link Master PL EC 8P IP67 | IO-Link master with EtherCat interface, max. 8 IO-Link ports / max. 12 digital inputs / max. 8 digital outputs, IP 65 / IP 67, Ambient temperature -25...60 °C |
| AL1100 | IO-Link Master SL PN 4P IP67 | IO-Link master with Profinet interface, max. 4 IO-Link ports / max. 8 digital inputs / max. 4 digital outputs, IP 65 / IP 66 / IP 67, Ambient temperature -25...60 °C |
| AL1101 | IO-Link Master SL PN 4P IP69K | IO-Link master with Profinet interface, max. 4 IO-Link ports / max. 8 digital inputs / max. 4 digital outputs, IP 65 / IP 67, Ambient temperature -25...60 °C |
| AL1102 | IO-Link Master SL PN 8P IP67 | IO-Link master with Profinet interface, max. 8 IO-Link ports / max. 16 digital inputs / max. 8 digital outputs, IP 65 / IP 66 / IP 67, Ambient temperature -25...60 °C |
| AL1103 | IO-Link Master SL PN 8P IP69K | IO-Link master with Profinet interface, max. 8 IO-Link ports / max. 16 digital inputs / max. 8 digital outputs, IP 65 / IP 67, Ambient temperature -25...60 °C |
| AL1120 | IO-Link Master SL EIP 4P IP67 | IO-Link master with EtherNet/IP interface, max. 4 IO-Link ports / max. 8 digital inputs / max. 4 digital outputs, IP 65 / IP 66 / IP 67, Ambient temperature -25...60 °C |
| AL1121 | IO-Link Master SL EIP 4P IP69K | IO-Link master with EtherNet/IP interface, max. 4 IO-Link ports / max. 8 digital inputs / max. 4 digital outputs, IP 65 / IP 67, Ambient temperature -25...60 °C |
| AL1122 | IO-Link Master SL EIP 8P IP67 | IO-Link master with EtherNet/IP interface, max. 8 IO-Link ports / max. 16 digital inputs / max. 8 digital outputs, IP 65 / IP 66 / IP 67, Ambient temperature -25...60 °C |
| AL1123 | IO-Link Master SL EIP 8P IP69K | IO-Link master with EtherNet/IP interface, max. 8 IO-Link ports / max. 16 digital inputs / max. 8 digital outputs, IP 65 / IP 67, Ambient temperature -25...60 °C |
| AL1200 | IO-Link Master PL PN 4P IP67 | IO-Link master with Profinet interface, max. 4 IO-Link ports / max. 8 digital inputs / max. 4 digital outputs, IP 65 / IP 66 / IP 67, Ambient temperature -25...60 °C |
| AL1202 | IO-Link Master PL PN 8P IP67 | IO-Link master with Profinet interface, max. 8 IO-Link ports / max. 12 digital inputs / max. 8 digital outputs, IP 65 / IP 66 / IP 67, Ambient temperature -25...60 °C |
| AL1220 | IO-Link Master PL EIP 4P IP67 | IO-Link master with EtherNet/IP interface, max. 4 IO-Link ports / max. 8 digital inputs / max. 4 digital outputs, IP 65 / IP 66 / IP 67, Ambient temperature -25...60 °C |
| AL1222 | IO-Link Master PL EIP 8P IP67 | IO-Link master with EtherNet/IP interface, max. 8 IO-Link ports / max. 12 digital inputs / max. 8 digital outputs, IP 65 / IP 66 / IP 67, Ambient temperature -25...60 °C |
AL1300
|
IO-Link Master DL PN 4P IP67 | IO-Link master DataLine; Number of digital inputs 8; Number of digital outputs 4; IP 65; IP 66; IP 67 |
AL1301
|
IO-Link Master DL PN 4P IP69K | IO-Link master DataLine; Number of digital inputs 8; Number of digital outputs 4; IP 65; IP 66; IP 67; IP 69K; (operation with stainless steel protective caps: IP 69K) |
AL1302
|
IO-Link Master DL PN 8P IP67 | IO-Link master DataLine; Number of digital inputs 16; Number of digital outputs 8; IP 65; IP 66; IP 67 |
AL1303
|
IO-Link Master DL PN 8P IP69K | IO-Link master DataLine; Number of digital inputs 16; Number of digital outputs 8; IP 65; IP 66; IP 67; IP 69K; (operation with stainless steel protective caps: IP 69K) |
AL1320
|
IO-Link Master DL EIP 4P IP67 | IO-Link master DataLine; Number of digital inputs 8; Number of digital outputs 4; IP 65; IP 66; IP 67 |
AL1321
|
IO-Link Master DL EIP 4P IP69K | IO-Link master DataLine; Number of digital inputs 8; Number of digital outputs 4; IP 65; IP 66; IP 67; IP 69K; (operation with stainless steel protective caps: IP 69K) |
AL1322
|
IO-Link Master DL EIP 8P IP67 | IO-Link master DataLine; Number of digital inputs 16; Number of digital outputs 8; IP 65; IP 66; IP 67 |
AL1323
|
IO-Link Master DL EIP 8P IP69K | IO-Link master DataLine; Number of digital inputs 16; Number of digital outputs 8; IP 65; IP 66; IP 67; IP 69K; (operation with stainless steel protective caps: IP 69K) |
AL1330
|
IO-Link Master DL EC 4P IP67 | IO-Link master DataLine; Number of digital inputs 8; Number of digital outputs 4; IP 65; IP 66; IP 67 |
AL1331
|
IO-Link Master DL EC 4P IP69K | IO-Link master DataLine; Number of digital inputs 8; Number of digital outputs 4; IP 65; IP 66; IP 67; IP 69K; (operation with stainless steel protective caps: IP 69K) |
AL1332
|
IO-Link Master DL EC 8P IP67 | IO-Link master DataLine; Number of digital inputs 16; Number of digital outputs 8; IP 65; IP 66; IP 67 |
AL1333
|
IO-Link Master DL EC 8P IP69K | IO-Link master DataLine; Number of digital inputs 16; Number of digital outputs 8; IP 65; IP 66; IP 67; IP 69K; (operation with stainless steel protective caps: IP 69K) |
AL1340
|
IO-Link Master DL MB 4P IP67 | IO-Link master DataLine; Number of digital inputs 8; Number of digital outputs 4; IP 65; IP 66; IP 67 |
AL1341
|
IO-Link Master DL MB 4P IP69K | IO-Link master DataLine; Number of digital inputs 8; Number of digital outputs 4; IP 65; IP 66; IP 67; IP 69K; (operation with stainless steel protective caps: IP 69K) |
AL1342
|
IO-Link Master DL MB 8P IP67 | IO-Link master DataLine; Number of digital inputs 16; Number of digital outputs 8; IP 65; IP 66; IP 67 |
AL1343
|
IO-Link Master DL MB 8P IP69K | IO-Link master DataLine; Number of digital inputs 16; Number of digital outputs 8; IP 65; IP 66; IP 67; IP 69K; (operation with stainless steel protective caps: IP 69K) |
| AL1900 | IO-Link Master CL PN 8P IP20 | IO-Link master CabinetLine; Number of digital inputs 8; Number of digital outputs 8; IP 20 |
| AL1920 | IO-Link Master CL EIP 8P IP20 | IO-Link master CabinetLine; Number of digital inputs 8; Number of digital outputs 8; IP 20 |
| AL1930 | IO-Link Master CL EC 8P IP20 | IO-Link master CabinetLine; Number of digital inputs 8; Number of digital outputs 8; IP 20 |
| AL1940 | IO-Link Master CL MB 8P IP20 | IO-Link master CabinetLine; Number of digital inputs 8; Number of digital outputs 8; IP 20 |
| AY1000 | IO-Link Master CL PN 8P IP20 | IO-Link master CabinetLine; 105.3 x 45.2 x 113.6 mm; Number of digital inputs 18; Number of digital outputs 10; IP 20 |
| AY1020 | IO-Link Master CL EIP 8P IP20 | IO-Link master CabinetLine; 105.3 x 45.2 x 113.6 mm; Number of digital inputs 18; Number of digital outputs 10; IP 20 |
| ZZ1100 | STARTER KIT IO-LINK | IO-Link master starter kit |