JUAL IFM ecomat200 Power supplies - Electronic 24 V DC circuit breakers

Electronic 24 V DC fuses

Electronic fuses permanently monitor the 24 V secondary circuit and reliably switch it off in the event of a failure. These electronic circuit breakers will also switch off circuits in cases where mechanical circuit breakers often do not trigger, e.g. in case of overload of a circuit with long cables.
The system has a modular structure and consists of a feed module and side-by-side mountable fuse modules. These modules can be mounted next to the head module via a simple clip mechanism, completely without any bridges or jumpers. Easy mounting and minimised wiring complexity save cost and time. With the standard version the user can connect up to 10 and with the IO-Link version up to 8 safety modules to the feed module.
The fuse modules feature an LED for signalling if the module has triggered, if it is active and in how far it is utilised. Each module is equipped with two channels. By means of a pushbutton, each channel of a fuse module can be activated, deactivated or reset individually. The IO-Link version allows remote configuration and operation of the modules.



DF1100 Fuse/Standard/24VDC/Module Supply module, standard, Circuit protection with monitoring function for the 24 V DC secondary circuit. Modular and selective protection in plant and machinery., Input current (max. total current) 40 A, for circuit protection modules DF12xx, IP 20, Ambient temperature -25...60 °C, push-in terminals, contact lever/strip
DF1208 Fuse/Standard/24VDC/8A Circuit protection module, standard, Circuit protection with monitoring function for the 24 V DC secondary circuit. Modular and selective protection in plant and machinery., Nominal current (Fail-safe element) 1 x 8 A, for supply module DF1100, IP 20, Ambient temperature -25...60 °C, push-in terminals, contact lever/strip
DF1210 Fuse/Standard/24VDC/10A Circuit protection module, standard, Circuit protection with monitoring function for the 24 V DC secondary circuit. Modular and selective protection in plant and machinery., Nominal current (Fail-safe element) 1 x 10 A, for supply module DF1100, IP 20, Ambient temperature -25...60 °C, push-in terminals, contact lever/strip
DF1212 Fuse/Standard/24VDC/2x2A Circuit protection module, standard, Circuit protection with monitoring function for the 24 V DC secondary circuit. Modular and selective protection in plant and machinery., Nominal current (Fail-safe element) 2 x 2 A, for supply module DF1100, IP 20, Ambient temperature -25...60 °C, push-in terminals, contact lever/strip
DF1214 Fuse/Standard/24VDC/2x4A Circuit protection module, standard, Circuit protection with monitoring function for the 24 V DC secondary circuit. Modular and selective protection in plant and machinery., Nominal current (Fail-safe element) 2 x 4 A, for supply module DF1100, IP 20, Ambient temperature -25...60 °C, push-in terminals, contact lever/strip
DF1216 Fuse/Standard/24VDC/2x6A Circuit protection module, standard, Circuit protection with monitoring function for the 24 V DC secondary circuit. Modular and selective protection in plant and machinery., Nominal current (Fail-safe element) 2 x 6 A, for supply module DF1100, IP 20, Ambient temperature -25...60 °C, push-in terminals, contact lever/strip
DF2100  Fuse/IO-Link/24VDC/Module Supply module, IO-Link, Circuit protection with monitoring function for the 24 V DC secondary circuit. Modular and selective protection in plant and machinery. Via IO-Link detection of triggering cause and current and voltage measurement in each channel., Input current (max. total current) 40 A, for circuit protection modules DF22xx, IP 20, Ambient temperature -25...60 °C, push-in terminals, contact lever/strip
DF2101 Fuse/IO-Link/24VDC/Module Supply module, IO-Link, Circuit protection with monitoring function for the 24 V DC secondary circuit. Modular and selective protection in plant and machinery. Via IO-Link detection of triggering cause and current and voltage measurement in each channel., Input current (max. total current) 40 A, for circuit protection modules DF22xx, IP 20, Ambient temperature -25...60 °C, push-in terminals, contact lever/strip
DF2208 Fuse/IO-Link/24VDC/8A Circuit protection module, IO-Link, Circuit protection with monitoring function for the 24 V DC secondary circuit. Modular and selective protection in plant and machinery. Via IO-Link detection of triggering cause and current and voltage measurement in each channel., Nominal current (Fail-safe element) 1 x 8 A, for supply module DF2100, IP 20, Ambient temperature -25...60 °C, push-in terminals, contact lever/strip
DF2210 Fuse/IO-Link/24VDC/10A Circuit protection module, IO-Link, Circuit protection with monitoring function for the 24 V DC secondary circuit. Modular and selective protection in plant and machinery. Via IO-Link detection of triggering cause and current and voltage measurement in each channel., Nominal current (Fail-safe element) 1 x 10 A, for supply module DF2100, IP 20, Ambient temperature -25...60 °C, push-in terminals, contact lever/strip
DF2212 Fuse/IO-Link/24VDC/2x2A Circuit protection module, IO-Link, Circuit protection with monitoring function for the 24 V DC secondary circuit. Modular and selective protection in plant and machinery. Via IO-Link detection of triggering cause and current and voltage measurement in each channel., Nominal current (Fail-safe element) 2 x 2 A, for supply module DF2100, IP 20, Ambient temperature -25...60 °C, push-in terminals, contact lever/strip
DF2214 Fuse/IO-Link/24VDC/2x4A Circuit protection module, IO-Link, Circuit protection with monitoring function for the 24 V DC secondary circuit. Modular and selective protection in plant and machinery. Via IO-Link detection of triggering cause and current and voltage measurement in each channel., Nominal current (Fail-safe element) 2 x 4 A, for supply module DF2100, IP 20, Ambient temperature -25...60 °C, push-in terminals, contact lever/strip
DF2216 Fuse/IO-Link/24VDC/2x6A Circuit protection module, IO-Link, Circuit protection with monitoring function for the 24 V DC secondary circuit. Modular and selective protection in plant and machinery. Via IO-Link detection of triggering cause and current and voltage measurement in each channel., Nominal current (Fail-safe element) 2 x 6 A, for supply module DF2100, IP 20, Ambient temperature -25...60 °C, push-in terminals, contact lever/strip

JUAL IFM efector100 Inductive sensors - Area sensors with long sensing range

Inductive sensors - Area sensors with long sensing range ...