JUAL IFM efector100 Fail-safe inductive sensors

Fail-safe inductive sensors

  • Certification to EN 60947-5-3 for electromechanical controlgear
  • Ensuring operator and machine safety
  • No special actuator for electronic fail-safe sensors required
  • Connection of the sensors to safety plc or safe AS-i module
  • Series connection of sensors and contacts possible


GF711S GIFA4004-2PS/SIL2/V4A/US Fail-safe inductive sensor; M12 x 1 / L = 70 mm; 2 x OSSD (A1 and A2); DC PNP; M12 Connector; IP 65; IP 67; Ambient temperature -25...70 °C
GG505S GIGA-4015-US /V4A Fail-safe inductive sensor; M18 x 1 / L = 90 mm; clock signal; DC; M12 Connector; IP 68; IP 69K; (to EN 60529); Ambient temperature -25...70 °C
GG507S GIGA-4010-US Fail-safe inductive sensor; M18 x 1 / L = 90.5 mm; clock signal; DC; M12 Connector; IP 68; IP 69K; (to EN 60529); Ambient temperature -25...70 °C
GG711S GIGA4008-2PS/SIL2/V4A/US Fail-safe inductive sensor; M18 x 1 / L = 70.5 mm; 2 x OSSD (A1 and A2); DC PNP; M12 Connector; IP 65; IP 67; Ambient temperature -25...70 °C
GG712S GIGA4005-2PS/SIL2/US Fail-safe inductive sensor; M18 x 1 / L = 70 mm; 2 x OSSD (A1 and A2); DC PNP; M12 Connector; IP 65; IP 67; Ambient temperature -25...70 °C
GG714S GIGA4008-2PS/SIL2/V4A/US Fail-safe inductive sensor; M18 x 1 / L = 71.5 mm; 2 x OSSD (A1 and A2); DC PNP; M12 Connector; IP 65; IP 67; IP 69K; (with ifm socket duly screwed on); Ambient temperature -40...70 °C
GG851S GIGA4005B2PO/SIL2/US Fail-safe inductive sensor; M18 x 1 / L = 86.5 mm; 2 x OSSD (A1 and A2); DC PNP; M12 Connector; IP 65; IP 67; Ambient temperature -25...70 °C
GI505S GIIA-4030-US /V4A Fail-safe inductive sensor; M30 x 1.5 / L = 80 mm; clock signal; DC; M12 Connector; IP 68; IP 69K; (to EN 60529); Ambient temperature 0...70 °C
GI506S GIIA-4030-3PT/SIL3/V4A/US Fail-safe inductive sensor; M30 x 1.5 / L = 80 mm; clock signal; DC; M12 Connector; IP 68; IP 69K; (to EN 60529); Ambient temperature 0...70 °C
GI701S GIIA-4030-US/2OSSD/V4A Fail-safe inductive sensor; M30 x 1.5 / L = 80 mm; 2 x OSSD (A1 and A2); DC PNP; M12 Connector; IP 68; IP 69K; Ambient temperature -25...70 °C
GI711S GIIA4015-2PS/SIL2/V4A/US Fail-safe inductive sensor; M30 x 1.5 / L = 70 mm; 2 x OSSD (A1 and A2); DC PNP; M12 Connector; IP 65; IP 67; Ambient temperature -25...70 °C
GI712S GIIA4010-2PS/SIL2/US Fail-safe inductive sensor; M30 x 1.5 / L = 70 mm; 2 x OSSD (A1 and A2); DC PNP; M12 Connector; IP 65; IP 67; Ambient temperature -25...70 °C
GM504S GIMC-4030-US Fail-safe inductive sensor; 40 x 40 x 66 mm; clock signal; DC; M12 Connector; IP 65; IP 67; (to EN 60529); Ambient temperature -25...70 °C
GM505S GIMC-4035-US Fail-safe inductive sensor; 40 x 40 x 66 mm; clock signal; DC; M12 Connector; IP 65; IP 67; (to EN 60529); Ambient temperature -25...70 °C
GM701S GIMC-4030-US/2OSSD Fail-safe inductive sensor; 40 x 40 x 66 mm; 2 x OSSD (A1 and A2); DC PNP; M12 Connector; IP 65; IP 67; Ambient temperature -25...70 °C
GM705S GIMC-4045-US/2OSSD Fail-safe inductive sensor; 40 x 40 x 66 mm; 2 x OSSD (A1 and A2); DC PNP; M12 Connector; IP 65; IP 67; Ambient temperature -25...60 °C

JUAL IFM efector100 Inductive sensors - Area sensors with long sensing range

Inductive sensors - Area sensors with long sensing range ...