IE5215 IEA3001-BPOG/V4A/US-100-DPS OL Inductive sensor; M8 x 1 / L = 70 mm; Sensing range 1 mm flush mountable; normally open; DC PNP; M12 Connector; IP 67; 3-wire; Ambient temperature -25...80 °C; Switching frequency 2000 Hz
IE5295 IEB3002-BPKG/V4A/US-104-DPS/RT Inductive sensor; M8 x 1 / L = 55 mm; Sensing range 2 mm non-flush mountable; normally open; DC PNP; M12 Connector; IP 67; 3-wire; Ambient temperature -25...80 °C; Switching frequency 2000 Hz
IE5379 IEB3002BBPKG/V4A/US Inductive sensor; M8 x 1 / L = 50 mm; Sensing range 2 mm flush mountable; normally open; DC PNP; M12 Connector; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 1000 Hz
IE5392 IEA3002BBPKG/V4A/US Inductive sensor; M8 x 1 / L = 70 mm; Sensing range 2 mm flush mountable; normally open; DC PNP; M12 Connector; IP 67; 3-wire; Ambient temperature 0...100 °C; Switching frequency 1000 Hz
IF5394 IFA3004-BPKG/V4A/6M Inductive sensor; M12 x 1 / L = 71 mm; Sensing range 4 mm non-flush mountable; normally open; DC PNP; 6 m PVC-Cable; IP 67; 3-wire; Ambient temperature -25...80 °C; Switching frequency 400 Hz
IF5395 IFA3002-BPKG/V4A/6M Inductive sensor; M12 x 1 / L = 71 mm; Sensing range 2 mm flush mountable; normally open; DC PNP; 6 m PVC-Cable; IP 67; 3-wire; Ambient temperature -25...80 °C; Switching frequency 800 Hz
IF5514 IFK3002-BPOG/V4A/US-100/OLED Inductive sensor; M12 x 1 / L = 59 mm; Sensing range 2 mm flush mountable; normally open; DC PNP; M12 Connector; IP 67; 3-wire; Ambient temperature -25...80 °C; Switching frequency 1100 Hz
IF5594 IFA3004-BPKG/V4A/US-100-DPS Inductive sensor; M12 x 1 / L = 83 mm; Sensing range 4 mm non-flush mountable; normally open; DC PNP; M12 Connector; IP 67; 3-wire; Ambient temperature -25...80 °C; Switching frequency 400 Hz
IF5759 IFA2002-FRKG/V4A/US-100-IRF RT Inductive sensor; M12 x 1 / L = 83 mm; Sensing range 2 mm flush mountable; normally open / normally closed; (selectable); DC PNP/NPN; M12 Connector; IP 67; 2-wire; Ambient temperature -25...80 °C; Switching frequency 1100 Hz
IF5760 IFA2004-FRKG/V4A/US-100-IRF RT Inductive sensor; M12 x 1 / L = 83 mm; Sensing range 4 mm non-flush mountable; normally open / normally closed; (selectable); DC PNP/NPN; M12 Connector; IP 67; 2-wire; Ambient temperature -25...80 °C; Switching frequency 1500 Hz
IF5796 IFB3004-BPKG/V4A/US-100-DPS Inductive sensor; M12 x 1 / L = 44 mm; Sensing range 4 mm non-flush mountable; normally open; DC PNP; M12 Connector; IP 67; 3-wire; Ambient temperature -25...80 °C; Switching frequency 1400 Hz
IF5807 IFG3004-BPKG/V4A/US-104-DPS Inductive sensor; Ø 11 / L = 60 mm; Sensing range 4 mm non-flush mountable; normally open; DC PNP; M12 Connector; IP 67; 3-wire; Ambient temperature -25...80 °C; Switching frequency 1400 Hz
IF5813 IFK3004-BPKG/V4A/US-100-DPS/AU Inductive sensor; M12 x 1 / L = 59 mm; Sensing range 4 mm non-flush mountable; normally open; DC PNP; M12 Connector; IP 67; 3-wire; Ambient temperature -25...80 °C; Switching frequency 1400 Hz
IF5815 IFB3002-BPKG/V4A/US-100-DPS/AU Inductive sensor; M12 x 1 / L = 44 mm; Sensing range 2 mm flush mountable; normally open; DC PNP; M12 Connector; IP 67; 3-wire; Ambient temperature -25...80 °C; Switching frequency 1200 Hz
IF5851 IFA3002-BPKG/V4A/US-100-DPS Inductive sensor; M12 x 1 / L = 83 mm; Sensing range 2 mm flush mountable; normally open; DC PNP; M12 Connector; IP 67; 3-wire; Ambient temperature -25...80 °C; Switching frequency 800 Hz
IF5878 IFK3003BBPKG/V4A/6M Inductive sensor; M12 x 1 mm; Sensing range 3 mm flush mountable; normally open; DC PNP; 6 m PVC-Cable; IP 67; 3-wire; Ambient temperature -25...80 °C; Switching frequency 400 Hz
IFT200 IFB3007-BPKG/M/V4A/US-104-DPS Inductive sensor; M12 x 1 / L = 50 mm; Sensing range 7 mm non-flush mountable; normally open; DC PNP; M12 Connector; IP 68; IP 69K; ("COP"); 3-wire; Ambient temperature 0...100 °C; Switching frequency 800 Hz
IFT201 IFB3007-APKG/M/V4A/US-104-DPO Inductive sensor; M12 x 1 / L = 50 mm; Sensing range 7 mm non-flush mountable; normally closed; DC PNP; M12 Connector; IP 68; IP 69K; ("COP"); 3-wire; Ambient temperature 0...100 °C; Switching frequency 800 Hz
IFT202 IFKC007-ASKG/M/V4A/US-104-DRS Inductive sensor; M12 x 1 / L = 70 mm; Sensing range 7 mm non-flush mountable; normally open; DC PNP/NPN; M12 Connector; IP 68; IP 69K; 2-wire,3-wire; Ambient temperature 0...100 °C; Switching frequency 700 Hz
IFT203 IFB3004BBPKG/M/V4A/US-104-DPS Inductive sensor; M12 x 1 / L = 45 mm; Sensing range 4 mm flush mountable; normally open; DC PNP; M12 Connector; IP 68; IP 69K; ("COP"); 3-wire; Ambient temperature 0...100 °C; Switching frequency 800 Hz
IFT204 IFB3004BAPKG/M/V4A/US-104-DPO Inductive sensor; M12 x 1 / L = 45 mm; Sensing range 4 mm flush mountable; normally closed; DC PNP; M12 Connector; IP 68; IP 69K; ("COP"); 3-wire; Ambient temperature 0...100 °C; Switching frequency 800 Hz
IFT205 IFKC004BASKG/M/V4A/US-104-DRS Inductive sensor; M12 x 1 / L = 70 mm; Sensing range 4 mm flush mountable; normally open; DC PNP/NPN; M12 Connector; IP 68; IP 69K; 2-wire,3-wire; Ambient temperature 0...100 °C; Switching frequency 500 Hz
IFT206 IFB3004BBPKG/M/V4A/6M/WH Inductive sensor; M12 x 1 / L = 50 mm; Sensing range 4 mm flush mountable; normally open; DC PNP; 6 m PVC-Cable; IP 68; IP 69K; ("COP"); 3-wire; Ambient temperature 0...100 °C; Switching frequency 800 Hz
IFT207 IFB3004BBPKG/M/V4A/10M/WH Inductive sensor; M12 x 1 / L = 50 mm; Sensing range 4 mm flush mountable; normally open; DC PNP; 10 m PVC-Cable; IP 68; IP 69K; ("COP"); 3-wire; Ambient temperature 0...100 °C; Switching frequency 800 Hz
IFT208 IFB3007-BPKG/M/V4A/6M/WH Inductive sensor; M12 x 1 / L = 61 mm; Sensing range 7 mm non-flush mountable; normally open; DC PNP; 6 m PVC-Cable; IP 68; IP 69K; ("COP"); 3-wire; Ambient temperature 0...100 °C; Switching frequency 800 Hz
IFT209 IFB3007-BPKG/M/V4A/10M/WH Inductive sensor; M12 x 1 / L = 61 mm; Sensing range 7 mm non-flush mountable; normally open; DC PNP; 10 m PVC-Cable; IP 68; IP 69K; ("COP"); 3-wire; Ambient temperature 0...100 °C; Switching frequency 800 Hz
IFT210 IFGC007-ASKG/M/V4A/US-104-DRS Inductive sensor; Ø 12 / L = 70 mm; Sensing range 7 mm non-flush mountable; normally open; DC PNP/NPN; M12 Connector; IP 68; IP 69K; 2-wire,3-wire; Ambient temperature 0...100 °C; Switching frequency 700 Hz
IFT213 IFKC007-ASKG/M/V4A/6M/WH Inductive sensor; M12 x 1 / L = 79 mm; Sensing range 7 mm non-flush mountable; normally open; DC PNP/NPN; 6 m PVC-Cable; IP 68; IP 69K; 2-wire,3-wire; Ambient temperature 0...100 °C; Switching frequency 700 Hz
IFT216 IFK3004BBPKG/M/V4A/US-104-DPS Inductive sensor; M12 x 1 / L = 70 mm; Sensing range 4 mm flush mountable; normally open; DC PNP; M12 Connector; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 700 Hz
IFT217 IFK3007-BPKG/M/V4A/US-104-DPS Inductive sensor; M12 x 1 / L = 70 mm; Sensing range 7 mm non-flush mountable; normally open; DC PNP; M12 Connector; IP 68; IP 69K; ("COP"); 3-wire; Ambient temperature 0...100 °C; Switching frequency 800 Hz
IFT222 IFB3007-ANKG/M/V4A/US-104-DNS Inductive sensor; M12 x 1 / L = 50 mm; Sensing range 7 mm non-flush mountable; normally open; DC NPN; M12 Connector; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 700 Hz
IFT230 IFB3004-BPKG/M/V4A/US-104-DPS Inductive sensor; M12 x 1 / L = 50 mm; Sensing range 4 mm non-flush mountable; normally open; DC PNP; M12 Connector; IP 68; IP 69K; ("COP"); 3-wire; Ambient temperature 0...100 °C; Switching frequency 800 Hz
IFT240 IFK3003BBPKG/AM/US-104-DPS Inductive sensor; M12 x 1 / L = 60 mm; Sensing range 3 mm flush mountable; normally open; DC PNP; M12 Connector; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 100 Hz
IFT241 IFKC007-ASKG/M/V4A/0.9M/PH/AS Inductive sensor; M12 x 1 / L = 79 mm; Sensing range 7 mm non-flush mountable; normally open; DC PNP/NPN; 0.9 m PUR-Cable; M8 Connector; IP 68; IP 69K; ("COP"); 2-wire,3-wire; Ambient temperature 0...100 °C; Switching frequency 700 Hz
IFT242 IFKC007-ASKG/M/V4A/0.4M/PH/AS Inductive sensor; M12 x 1 / L = 79 mm; Sensing range 7 mm non-flush mountable; normally open; DC PNP/NPN; 0.4 m PUR-Cable; M8 Connector; IP 68; IP 69K; ("COP"); 2-wire,3-wire; Ambient temperature 0...100 °C; Switching frequency 700 Hz
IFT243 IFG3003BBPKG/AM/US-104-DPS Inductive sensor; Ø 12 / L = 60 mm; Sensing range 3 mm flush mountable; normally open; DC PNP; M12 Connector; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 100 Hz
IFT244 IFK3003BANKG/AM/US-104-DNS Inductive sensor; M12 x 1 / L = 60 mm; Sensing range 3 mm flush mountable; normally open; DC NPN; M12 Connector; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 100 Hz
IFT245 IFK3006-BPKG/AM/P/US-104-DPS Inductive sensor; M12 x 1 / L = 70 mm; Sensing range 6 mm non-flush mountable; normally open; DC PNP; M12 Connector; IP 65; IP 67; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 500 Hz
IFT246 IFK3006-ANKG/AM/P/US-104-DNS Inductive sensor; M12 x 1 / L = 70 mm; Sensing range 6 mm non-flush mountable; normally open; DC NPN; M12 Connector; IP 65; IP 67; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 500 Hz
IFT249 IFKC007-ASKG/M/V4A/1M/WH Inductive sensor; M12 x 1 / L = 79 mm; Sensing range 7 mm non-flush mountable; normally open; DC PNP/NPN; 1 m PVC-Cable; IP 68; IP 69K; 2-wire,3-wire; Ambient temperature 0...100 °C; Switching frequency 700 Hz
IFT257 IFB3004BBPKG/AM/V4A/US-104 Inductive sensor; M12 x 1 / L = 45 mm; Sensing range 4 mm flush mountable; normally open; DC PNP; M12 Connector; IP 65; IP 66; IP 67; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 100 Hz
IG5502 IGA3005-BPKG/V4A/6M Inductive sensor; M18 x 1 / L = 80 mm; Sensing range 5 mm flush mountable; normally open; DC PNP; 6 m PVC-Cable; IP 67; 3-wire; Ambient temperature -25...80 °C; Switching frequency 500 Hz
IG5558 IGA3008-BPKG/V4A/6M Inductive sensor; M18 x 1 / L = 80 mm; Sensing range 8 mm non-flush mountable; normally open; DC PNP; 6 m PVC-Cable; IP 67; 3-wire; Ambient temperature -25...80 °C; Switching frequency 300 Hz
IG5602 IGA3008-BPKG/V4A/US-100-DPS Inductive sensor; M18 x 1 / L = 90 mm; Sensing range 8 mm non-flush mountable; normally open; DC PNP; M12 Connector; IP 67; 3-wire; Ambient temperature -25...80 °C; Switching frequency 300 Hz
IG5806 IGA2005-FRKG/V4A/US-100-IRF/AU Inductive sensor; M18 x 1 / L = 90 mm; Sensing range 5 mm flush mountable; normally open / normally closed; (selectable); DC PNP/NPN; M12 Connector; IP 67; 2-wire; Ambient temperature -25...80 °C; Switching frequency 700 Hz
IG5813 IGA3005-BPKG/V4A/US-100-DPS Inductive sensor; M18 x 1 / L = 76 mm; Sensing range 5 mm flush mountable; normally open; DC PNP; M12 Connector; IP 67; 3-wire; Ambient temperature -25...80 °C; Switching frequency 500 Hz
IG5817 IGB3008-BPKG/V4A/US-100-DPS/AU Inductive sensor; M18 x 1 / L = 48 mm; Sensing range 8 mm non-flush mountable; normally open; DC PNP; M12 Connector; IP 67; 3-wire; Ambient temperature -25...80 °C; Switching frequency 200 Hz
IG5846 IGB4010-CPKG/V4A/US-104-DPA RT Inductive sensor; M18 x 1 / L = 45 mm; Sensing range 10 mm non-flush mountable; complementary; DC PNP; M12 Connector; IP 67; 3-wire; Ambient temperature -25...80 °C; Switching frequency 300 Hz
IG5927 IGA3005-BPKG/V4A/US-100-DPS/OL Inductive sensor; M18 x 1 / L = 90 mm; Sensing range 5 mm flush mountable; normally open; DC PNP; M12 Connector; IP 67; 3-wire; Ambient temperature -25...80 °C; Switching frequency 500 Hz
IGT001 IGK2012-ARKA/M/V4A/LS-104AK Inductive sensor; M18 x 1 / L = 70 mm; Sensing range 12 mm non-flush mountable; normally open; AC/DC; 1/2" Connector; IP 68; IP 69K; ("COP"); 2-wire; Ambient temperature 0...100 °C; Switching frequency 25 Hz AC / 300 Hz DC
IGT002 IGK2005-ARKA/M/V4A/LS-104AK Inductive sensor; M18 x 1 / L = 70 mm; Sensing range 5 mm flush mountable; normally open; AC/DC; 1/2" Connector; IP 68; IP 69K; ("COP"); 2-wire; Ambient temperature 0...100 °C; Switching frequency 25 Hz AC / 400 Hz DC
IGT200 IGB3012-BPKG/M/V4A/US-104-DPS Inductive sensor; M18 x 1 / L = 51 mm; Sensing range 12 mm non-flush mountable; normally open; DC PNP; M12 Connector; IP 68; IP 69K; ("COP"); 3-wire; Ambient temperature 0...100 °C; Switching frequency 300 Hz
IGT201 IGB3012-APKG/M/V4A/US-104-DPO Inductive sensor; M18 x 1 / L = 51 mm; Sensing range 12 mm non-flush mountable; normally closed; DC PNP; M12 Connector; IP 68; IP 69K; ("COP"); 3-wire; Ambient temperature 0...100 °C; Switching frequency 300 Hz
IGT202 IGKC012-ASKG/M/V4A/US-104-DRS Inductive sensor; M18 x 1 / L = 70 mm; Sensing range 12 mm non-flush mountable; normally open; DC PNP/NPN; M12 Connector; IP 68; IP 69K; 2-wire,3-wire; Ambient temperature 0...100 °C; Switching frequency 300 Hz
IGT203 IGB3008BBPKG/M/V4A/US-104-DPS Inductive sensor; M18 x 1 / L = 46 mm; Sensing range 8 mm flush mountable; normally open; DC PNP; M12 Connector; IP 68; IP 69K; ("COP"); 3-wire; Ambient temperature 0...100 °C; Switching frequency 600 Hz
IGT204 IGB3008BAPKG/M/V4A/US-104-DPO Inductive sensor; M18 x 1 / L = 46 mm; Sensing range 8 mm flush mountable; normally closed; DC PNP; M12 Connector; IP 68; IP 69K; ("COP"); 3-wire; Ambient temperature 0...100 °C; Switching frequency 600 Hz
IGT205 IGKC008BASKG/M/V4A/US-104-DRS Inductive sensor; M18 x 1 / L = 70 mm; Sensing range 8 mm flush mountable; normally open; DC PNP/NPN; M12 Connector; IP 68; IP 69K; ("COP"); 2-wire,3-wire; Ambient temperature 0...100 °C; Switching frequency 400 Hz
IGT206 IGB3008BBPKG/M/V4A/6M/WH Inductive sensor; M18 x 1 / L = 57 mm; Sensing range 8 mm flush mountable; normally open; DC PNP; 6 m PVC-Cable; IP 68; IP 69K; ("COP"); 3-wire; Ambient temperature 0...100 °C; Switching frequency 600 Hz
IGT207 IGB3008BBPKG/M/V4A/10M/WH Inductive sensor; M18 x 1 / L = 57 mm; Sensing range 8 mm flush mountable; normally open; DC PNP; 10 m PVC-Cable; IP 68; IP 69K; ("COP"); 3-wire; Ambient temperature 0...100 °C; Switching frequency 600 Hz
IGT208 IGB3012-BPKG/M/V4A/6M/WH Inductive sensor; M18 x 1 / L = 62 mm; Sensing range 12 mm non-flush mountable; normally open; DC PNP; 6 m PVC-Cable; IP 68; IP 69K; ("COP"); 3-wire; Ambient temperature 0...100 °C; Switching frequency 300 Hz
IGT209 IGB3012-BPKG/M/V4A/10M/WH Inductive sensor; M18 x 1 / L = 62 mm; Sensing range 12 mm non-flush mountable; normally open; DC PNP; 10 m PVC-Cable; IP 68; IP 69K; ("COP"); 3-wire; Ambient temperature 0...100 °C; Switching frequency 300 Hz
IGT211 IGGC012-ASKG/M/V4A/US-104-DRS Inductive sensor; Ø 18 / L = 70 mm; Sensing range 12 mm non-flush mountable; normally open; DC PNP/NPN; M12 Connector; IP 68; IP 69K; 2-wire,3-wire; Ambient temperature 0...100 °C; Switching frequency 300 Hz
IGT213 IGKC012-ASKG/M/V4A/10M/WH Inductive sensor; M18 x 1 / L = 81 mm; Sensing range 12 mm non-flush mountable; normally open; DC PNP/NPN; 10 m PVC-Cable; IP 68; IP 69K; ("COP"); 2-wire,3-wire; Ambient temperature 0...100 °C; Switching frequency 300 Hz
IGT215 IGB3012-BPKG/M/V4A/25M/WH Inductive sensor; M18 x 1 / L = 62 mm; Sensing range 12 mm non-flush mountable; normally open; DC PNP; 25 m PVC-Cable; IP 68; IP 69K; ("COP"); 3-wire; Ambient temperature 0...100 °C; Switching frequency 300 Hz
IGT219 IGK3008BBPKG/M/V4A/US-104-DPS Inductive sensor; M18 x 1 / L = 70 mm; Sensing range 8 mm flush mountable; normally open; DC PNP; M12 Connector; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 400 Hz
IGT220 IGK3012-BPKG/M/V4A/US-104-DPS Inductive sensor; M18 x 1 / L = 70 mm; Sensing range 12 mm non-flush mountable; normally open; DC PNP; M12 Connector; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 300 Hz
IGT228 IGKC008BASKG/M/V4A/US-104-DRS Inductive sensor; M18 x 1 / L = 70 mm; Sensing range 8 mm flush mountable; normally open; DC PNP/NPN; M12 Connector; IP 68; IP 69K; 2-wire,3-wire; Ambient temperature 0...100 °C; Switching frequency 400 Hz
IGT237 IGB3005-BPKG/M/V4A/US-104-DPS Inductive sensor; M18 x 1 / L = 46 mm; Sensing range 5 mm flush mountable; normally open; DC PNP; M12 Connector; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 500 Hz
IGT238 IGB3008-BPKG/M/V4A/US-104-DPS Inductive sensor; M18 x 1 / L = 51 mm; Sensing range 8 mm non-flush mountable; normally open; DC PNP; M12 Connector; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 300 Hz
IGT240 IGKC008-ASKG/M/V4A/US-104-DRS Inductive sensor; M18 x 1 / L = 70 mm; Sensing range 8 mm non-flush mountable; normally open; DC PNP/NPN; M12 Connector; IP 68; IP 69K; 2-wire,3-wire; Ambient temperature 0...100 °C; Switching frequency 300 Hz
IGT241 IGA3008BBPKG/M/V4A/US-104-DPS Inductive sensor; M18 x 1 / L = 90 mm; Sensing range 8 mm flush mountable; normally open; DC PNP; M12 Connector; IP 67; 3-wire; Ambient temperature 0...100 °C; Switching frequency 400 Hz
IGT247 IGK3005-BPKG/AM/US-104-DPS Inductive sensor; M18 x 1 / L = 70 mm; Sensing range 5 mm flush mountable; normally open; DC PNP; M12 Connector; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 100 Hz
IGT248 IGK3005-ANKG/AM/US-104-DNS Inductive sensor; M18 x 1 / L = 70 mm; Sensing range 5 mm flush mountable; normally open; DC NPN; M12 Connector; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 100 Hz
IGT249 IGK3012-BPKG/AM/P/US-104-DPS Inductive sensor; M18 x 1 / L = 70 mm; Sensing range 12 mm non-flush mountable; normally open; DC PNP; M12 Connector; IP 65; IP 67; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 500 Hz
IGT250 IGK3012-ANKG/AM/P/US-104-DNS Inductive sensor; M18 x 1 / L = 70 mm; Sensing range 12 mm non-flush mountable; normally open; DC NPN; M12 Connector; IP 65; IP 67; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 500 Hz
IGT258 IGB3008BBPKG/AM/V4A/US-104 Inductive sensor; M18 x 1 / L = 45 mm; Sensing range 8 mm flush mountable; normally open; DC PNP; M12 Connector; IP 65; IP 66; IP 67; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 100 Hz
II503A IIK3025-BPKG/AM/P/US104/3G/3D Inductive sensor; M30 x 1.5 / L = 70 mm; Sensing range 25 mm non-flush mountable; normally open; DC PNP; M12 Connector; IP 67; (when used outside the hazardous area: IP 65, IP 67, IP 68, IP 69K); 3-wire; Ambient temperature -40...60 °C; Switching frequency 250 Hz
II5689 IIA3010-BPKG/V4A/US-100-DPS/AU Inductive sensor; M30 x 1.5 / L = 92 mm; Sensing range 10 mm flush mountable; normally open; DC PNP; M12 Connector; IP 67; 3-wire; Ambient temperature -25...80 °C; Switching frequency 250 Hz
II5729 IIA2015-FRKG/V4A/6M/PH Inductive sensor; M30 x 1.5 / L = 81 mm; Sensing range 15 mm non-flush mountable; normally open / normally closed; (selectable); DC PNP/NPN; 6 m PUR / PVC-Cable; IP 67; 2-wire; Ambient temperature -25...80 °C; Switching frequency 200 Hz
II5733 IIA2015-FRKG/V4A/US-100-IRF/RT Inductive sensor; M30 x 1.5 / L = 78 mm; Sensing range 15 mm non-flush mountable; normally open / normally closed; (selectable); DC PNP/NPN; M12 Connector; IP 67; 2-wire; Ambient temperature -25...80 °C; Switching frequency 200 Hz
II5751 IIA2010-FRKG/V4A/US-100-IRF/AU Inductive sensor; M30 x 1.5 / L = 92 mm; Sensing range 10 mm flush mountable; normally open / normally closed; (selectable); DC PNP/NPN; M12 Connector; IP 67; 2-wire; Ambient temperature -25...80 °C; Switching frequency 450 Hz
II5776 IIA3015-BPKG/V4A/US-100-DPS-AU Inductive sensor; M30 x 1.5 / L = 92 mm; Sensing range 15 mm non-flush mountable; normally open; DC PNP; M12 Connector; IP 67; 3-wire; Ambient temperature -25...80 °C; Switching frequency 200 Hz
II5807 IIA3010-BPKG/V4A/6M Inductive sensor; M30 x 1.5 / L = 81 mm; Sensing range 10 mm flush mountable; normally open; DC PNP; 6 m PVC-Cable; IP 67; 3-wire; Ambient temperature -25...80 °C; Switching frequency 250 Hz
IIC233 IIB3015BBPKG/AM/V4A/US-104 Inductive sensor; M30 x 1.5 / L = 50 mm; Sensing range 15 mm flush mountable; normally open; DC PNP; M12 Connector; IP 65; IP 66; IP 67; IP 68; IP 69K; 3-wire; Ambient temperature -40...85 °C; Switching frequency 50 Hz
IIT001 IIK2014BARKA/M/V4A/LS-104-AK Inductive sensor; M30 x 1.5 / L = 70 mm; Sensing range 14 mm flush mountable; normally open; AC/DC; 1/2" Connector; IP 68; IP 69K; ("COP"); 2-wire; Ambient temperature 0...100 °C; Switching frequency 25 Hz AC / 100 Hz DC
IIT002 IIK2022-ARKA/M/V4A/LS-104-AK Inductive sensor; M30 x 1.5 / L = 70 mm; Sensing range 22 mm non-flush mountable; normally open; AC/DC; 1/2" Connector; IP 68; IP 69K; ("COP"); 2-wire; Ambient temperature 0...100 °C; Switching frequency 25 Hz AC / 100 Hz DC
IIT200 IIB3022-BPKG/M/V4A/US-104-DPS Inductive sensor; M30 x 1.5 / L = 50 mm; Sensing range 22 mm non-flush mountable; normally open; DC PNP; M12 Connector; IP 68; IP 69K; ("COP"); 3-wire; Ambient temperature 0...100 °C; Switching frequency 100 Hz
IIT202 IIKC022-ASKG/M/V4A/US-104-DRS Inductive sensor; M30 x 1.5 / L = 70 mm; Sensing range 22 mm non-flush mountable; normally open; DC PNP/NPN; M12 Connector; IP 68; IP 69K; 2-wire,3-wire; Ambient temperature 0...100 °C; Switching frequency 100 Hz
IIT204 IIKC014BASKG/M/V4A/US-104-DRS Inductive sensor; M30 x 1.5 / L = 70 mm; Sensing range 14 mm flush mountable; normally open; DC PNP/NPN; M12 Connector; IP 68; IP 69K; 2-wire,3-wire; Ambient temperature 0...100 °C; Switching frequency 100 Hz
IIT205 IIB3014BBPKG/M/V4A/US-104-DPS Inductive sensor; M30 x 1.5 / L = 50 mm; Sensing range 14 mm flush mountable; normally open; DC PNP; M12 Connector; IP 68; IP 69K; ("COP"); 3-wire; Ambient temperature 0...100 °C; Switching frequency 100 Hz
IIT206 IIB3014BBPKG/M/V4A/10M/WH Inductive sensor; M30 x 1.5 / L = 59 mm; Sensing range 14 mm flush mountable; normally open; DC PNP; 10 m PVC-Cable; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 100 Hz
IIT207 IIB3022-BPKG/M/V4A/6M/WH Inductive sensor; M30 x 1.5 / L = 59 mm; Sensing range 22 mm non-flush mountable; normally open; DC PNP; 6 m PVC-Cable; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 100 Hz
IIT208 IIB3022-BPKG/M/V4A/10M/WH Inductive sensor; M30 x 1.5 / L = 59 mm; Sensing range 22 mm non-flush mountable; normally open; DC PNP; 10 m PVC-Cable; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 100 Hz
IIT209 IIB3014BBPKG/M/V4A/6M/WH Inductive sensor; M30 x 1.5 / L = 59 mm; Sensing range 14 mm flush mountable; normally open; DC PNP; 6 m PVC-Cable; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 100 Hz
IIT210 IIKC014BASKG/M/V4A/10M Inductive sensor; M30 x 1.5 / L = 81 mm; Sensing range 14 mm flush mountable; normally open; DC PNP/NPN; 10 m PVC-Cable; IP 68; IP 69K; 2-wire,3-wire; Ambient temperature 0...100 °C; Switching frequency 100 Hz
IIT212 IIK3015BBPKG/M/V4A/US104-DPS Inductive sensor; M30 x 1.5 / L = 70 mm; Sensing range 15 mm flush mountable; normally open; DC PNP; M12 Connector; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 100 Hz
IIT213 IIK3022-BPKG/M/V4A/US104-DPS Inductive sensor; M30 x 1.5 / L = 70 mm; Sensing range 22 mm non-flush mountable; normally open; DC PNP; M12 Connector; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 100 Hz
IIT216 IIK3010-BPKG/M/V4A/US-104-DPS Inductive sensor; M30 x 1.5 / L = 70 mm; Sensing range 10 mm flush mountable; normally open; DC PNP; M12 Connector; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 100 Hz
IIT218 IIK3015BAPKG/M/V4A/US104-DPO Inductive sensor; M30 x 1.5 / L = 70 mm; Sensing range 15 mm flush mountable; normally closed; DC PNP; M12 Connector; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 100 Hz
IIT219 IIK3022-APKG/M/V4A/US104-DPO Inductive sensor; M30 x 1.5 / L = 70 mm; Sensing range 22 mm non-flush mountable; normally closed; DC PNP; M12 Connector; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 100 Hz
IIT225 IIKC010-ASKG/M/V4A/US-104-DRS Inductive sensor; M30 x 1.5 / L = 70 mm; Sensing range 10 mm flush mountable; normally open; DC PNP/NPN; M12 Connector; IP 68; IP 69K; 2-wire,3-wire; Ambient temperature 0...100 °C; Switching frequency 100 Hz
IIT228 IIK3010-BPKG/AM/US-104-DPS Inductive sensor; M30 x 1.5 / L = 70 mm; Sensing range 10 mm flush mountable; normally open; DC PNP; M12 Connector; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 50 Hz
IIT230 IIK3010-ANKG/AM/US-104-DNS Inductive sensor; M30 x 1.5 / L = 70 mm; Sensing range 10 mm flush mountable; normally open; DC NPN; M12 Connector; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 50 Hz
IIT231 IIK3025-BPKG/AM/P/US-104-DPS Inductive sensor; M30 x 1.5 / L = 70 mm; Sensing range 25 mm non-flush mountable; normally open; DC PNP; M12 Connector; IP 65; IP 67; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 250 Hz
IIT232 IIK3025-ANKG/AM/P/US-104-DNS Inductive sensor; M30 x 1.5 / L = 70 mm; Sensing range 25 mm non-flush mountable; normally open; DC NPN; M12 Connector; IP 65; IP 67; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 250 Hz
IIT243 IIB3015BBPKG/AM/V4A/US-104 Inductive sensor; M30 x 1.5 / L = 50 mm; Sensing range 15 mm flush mountable; normally open; DC PNP; M12 Connector; IP 65; IP 66; IP 67; IP 68; IP 69K; 3-wire; Ambient temperature 0...100 °C; Switching frequency 50 Hz

JUAL IFM efector100 Inductive sensors - Area sensors with long sensing range