AS-Interface masters
- Easy two-wire wiring system
- High-performance controllers and gateways
- Graphic display for convenient configuration and diagnosis
- For use with different fieldbuses
| AC1027 | ControllerE 1Mstr DP RS232 | AS-i PROFIBUS DP ControllerE; Number of AS-i masters 1 |
| AC1028 | ControllerE 2Mstr DP RS232 | AS-i PROFIBUS DP ControllerE; Number of AS-i masters 1 |
| AC1318 | ControllerE M4 1Master DN | AS-i DeviceNet controller E, Use as decentralized controller and DeviceNet gateway, AS-i controllerwith DeviceNet interface Full master functions Graphic display, IP 20, Ambient temperature 0...60 °C |
| AC1324 | ControllerE M4 2Master DN | AS-i DeviceNet controller E, Use as decentralized controller and DeviceNet gateway, AS-i controllerwith DeviceNet interface Full master functions Graphic display, IP 20, Ambient temperature 0...60 °C |
| AC1331 | ControllerE M4 1Master CO | AS-i CANopen Controller E, Use as decentralized controller and CANopen gateway, AS-i controllerwith CANopen interface Full master functions Graphic display, IP 20, Ambient temperature 0...60 °C |
| AC1332 | ControllerE M4 2Master CO | AS-i CANopen Controller E, Use as decentralized controller and CANopen gateway, AS-i controllerwith CANopen interface Full master functions Graphic display, IP 20, Ambient temperature 0...60 °C |
| AC1357 | ControllerE M4 1Mstr Ethernet | AS-i controller E, Use as decentralised controller, AS-i controllerfreely programmable Full master functions Graphic display Ethernet programming interface, IP 20, Ambient temperature 0...60 °C |
| AC1358 | ControllerE M4 2Mstr Ethernet | AS-i controller E, Use as decentralised controller, AS-i controllerfreely programmable Full master functions Graphic display Ethernet programming interface, IP 20, Ambient temperature 0...60 °C |
| AC1365 | ControllerE M4 1Mstr DPV1 | AS-i DP controller E, use as a decentralised PLC and Profibus DP gateway, AS-i PLC with Profibus-DP interface Full master functions Graphic display, IP 20, Ambient temperature 0...60 °C |
| AC1366 | ControllerE M4 2Mstr DPV1 | AS-i DP controller E, use as a decentralised PLC and Profibus DP gateway, AS-i PLC with Profibus-DP interface Full master functions Graphic display, IP 20, Ambient temperature 0...60 °C |
| AC1375 | SmartLink M4 DP 1Master | SmartLink DP, Use as AS-i / Profibus DP gateway, AS-i gateway / Profibus DP Full master functions Graphic display, IP 20, Ambient temperature 0...60 °C |
| AC1376 | AS-i DP Gateway M4 2MSTR | AS-i DP gateway, Use as Profibus DP gateway with 2 AS-i masters, Full master functions Graphic display, IP 20, Ambient temperature 0...60 °C |
| AC1401 | AS-i Gateway 1Master PN | AS-i Profinet gateway, Use as AS-i Profinet gateway, AS-i master Ethernet configuration interface with dynamic web interface for configuration and diagnosis including remote maintenance Profinet RT device class B LCD colour display, IP 20, Ambient temperature 0...60 °C, terminals up to 2.5 mm² |
| AC1402 | AS-i Gateway 2Master PN | AS-i Profinet gateway, Use as AS-i Profinet gateway, AS-i master Ethernet configuration interface with dynamic web interface for configuration and diagnosis including remote maintenance Profinet RT device class B LCD colour display, IP 20, Ambient temperature 0...60 °C |
AC1403
|
SmartPLC DataLine 1ASi PN | SmartPLC DataLine with Profinet device interface, Housing for DIN rail mounting, AS-i master, Ethernet configuration interface with dynamic web interface for configuration and diagnosis including remote maintenance, LCD colour display, Device supply either via 24 V or AS-i (AS-i bus 1) |
| AC1404 | SmartPLC DataLine 2ASi PN | SmartPLC DataLine with Profinet device interface, Housing for DIN rail mounting, AS-i master, Ethernet configuration interface with dynamic web interface for configuration and diagnosis including remote maintenance, LCD colour display, Device supply either via 24 V or AS-i (AS-i bus 1) |
| AC1411 | AS-i Gateway 1Master PB | AS-i Profibus gateway, Use as Profibus gateway, AS-i master Ethernet configuration interface with dynamic web interface for configuration and diagnosis including remote maintenance Profibus DP (DPV0 + DPV1) LCD colour display, IP 20, Ambient temperature 0...60 °C, terminals up to 2.5 mm² |
| AC1412 | AS-i Gateway 2Master PB | AS-i Profibus gateway, Use as Profibus gateway, AS-i master Ethernet configuration interface with dynamic web interface for configuration and diagnosis including remote maintenance Profibus DP (DPV0 + DPV1) LCD colour display, IP 20, Ambient temperature 0...60 °C, terminals up to 2.5 mm² |
| AC1421 | AS-i Gateway 1Master EIP | AS-i EtherNet/IP gateway, Use as AS-i Ethernet/IP gateway, AS-i master Ethernet configuration interface with dynamic web interface for configuration and diagnosis including remote maintenance LCD colour display Device supply either via 24 V or AS-i (AS-i bus 1), IP 20, Ambient temperature 0...60 °C, terminals up to 2.5 mm² |
| AC1422 | AS-i Gateway 2Master EIP | AS-i EtherNet/IP gateway, Use as AS-i Ethernet/IP gateway, AS-i master Ethernet configuration interface with dynamic web interface for configuration and diagnosis including remote maintenance LCD colour display Device supply either via 24 V or AS-i (AS-i bus 1), IP 20, Ambient temperature 0...60 °C, terminals up to 2.5 mm² |
| AC1423 | SmartPLC DataLine 1ASi EIP | SmartPLC DataLine with EtherNet/IP device interface, Housing for DIN rail mounting, AS-i master, Ethernet configuration interface with dynamic web interface for configuration and diagnosis including remote maintenance, LCD colour display, Device supply either via 24 V or AS-i (AS-i bus 1) |
| AC1424 | SmartPLC DataLine 2ASi EIP | SmartPLC DataLine with EtherCAT slave interface, standard PLC and/or AS-i / EtherCAT gateway, AS-i master Ethernet configuration interface with dynamic web interface for configuration and diagnosis including remote maintenance LCD colour display Device supply either via 24 V or AS-i (AS-i bus 1), IP 20, Ambient temperature 0...60 °C, terminals up to 2.5 mm² |
| AC1433 | SmartPLC DataLine 1ASi ECAT | SmartPLC DataLine with EtherCAT slave interface, standard PLC and/or AS-i / EtherCAT gateway, AS-i master Ethernet configuration interface with dynamic web interface for configuration and diagnosis including remote maintenance LCD colour display Device supply either via 24 V or AS-i (AS-i bus 1), IP 20, Ambient temperature 0...60 °C, terminals up to 2.5 mm² |
| AC1434 | SmartPLC DataLine 2ASi ECAT | SmartPLC DataLine with EtherCAT slave interface, standard PLC and/or AS-i / EtherCAT gateway, AS-i master Ethernet configuration interface with dynamic web interface for configuration and diagnosis including remote maintenance LCD colour display Device supply either via 24 V or AS-i (AS-i bus 1), IP 20, Ambient temperature 0...60 °C, terminals up to 2.5 mm² |
| AC1434 | SmartPLC DataLine 2ASi ECAT | SmartPLC DataLine with EtherCAT slave interface, standard PLC and/or AS-i / EtherCAT gateway, AS-i master Ethernet configuration interface with dynamic web interface for configuration and diagnosis including remote maintenance LCD colour display Device supply either via 24 V or AS-i (AS-i bus 1), IP 20, Ambient temperature 0...60 °C, terminals up to 2.5 mm² |
| AC402S | SmartPLC SafeLine 2ASi PN | AS-i Profinet gateway with safe preprocessing, Use as AS-i Profinet gateway with safe preprocessing, Ethernet configuration interface with dynamic web interface for configuration and diagnosis including remote maintenance, Profinet RT device class B, LCD colour display, Integrated safety and non safety PLC, IP 20, Ambient temperature 0...45 °C |
| AC412S | SmartPLC SafeLine 2ASi PB | AS-i Profibus gateway, Einsatz als AS-i Profibus Gateway mit sicherer Vorverarbeitung, Ethernet configuration interface with dynamic web interface for configuration and diagnosis including remote maintenance, Profibus DP (DPV0 + DPV1), LCD colour display, Configuration and setup by configuration software CODESYS V3, IP 20, Ambient temperature 0...45 °C |
| AC422S | SmartPLC SafeLine 2ASi EIP | AS-i EtherNet/IP gateway with safe preprocessing, Use as AS-i Ethernet/IP gateway with safe preprocessing, Ethernet configuration interface with dynamic web interface for configuration and diagnosis including remote maintenance, LCD colour display, Integrated safety and non safety PLC, Configuration and setup by configuration software CODESYS V3, IP 20, Ambient temperature 0...45 °C |
| AC432S | SmartPLC SafeLine 2ASi ECAT | Housing for DIN rail mounting, Ethernet configuration interface with dynamic web interface for configuration and diagnosis including remote maintenance, LCD colour display, Configuration and setup by configuration software CODESYS V3, Complies with the requirements: EN ISO 13849-1: 2015 Category 4 PL e, IEC 61508: SIL 3 |