| AC1212 |
PowerSupply 230VAC 2x4A |
Power supply, 2 x 4 A,
AS-i system voltage for masters, sensors, actuators and modules, AS-i dual
power supply 115/230 V AC 2 x AS-i, Integrated data decoupling, IP 20,
Ambient temperature -10...60 °C, terminals up to 2.5 mm² |
| AC1221 |
PSU-1AC/ASI-1.9A |
Power supply, 1,9 A, AS-i system voltage for
masters, sensors, actuators and modules, AS-i power supply 100...240 V AC,
Integrated data decoupling, IP 20, Ambient temperature 0...70 °C, cage clamps |
| AC1226 |
PowerSupply 230VAC 2.8A |
Power supply, 2,8 A, AS-i
system voltage for masters, sensors, actuators and modules, AS-i power supply
115/230 V AC, Integrated data decoupling, Jumper to deactivate the AS-i
communication, NEC Class II Power Source, IP 20, Ambient temperature -10...70
°C, cage clamps |
| AC1236 |
PSU-1AC/ASI-2.8A |
Power supply, 2,8 A, AS-i system voltage for
masters, sensors, actuators and modules, AS-i power supply 100...240 V AC,
Integrated data decoupling, IP 20, Ambient temperature 0...70 °C, screw
terminals |
| AC1250 |
AS-i Data Decoupler |
AS-i data decoupling
module, IP 20, Ambient temperature 0...60 °C, terminals up to 2.5 mm² |
| AC1253 |
PSU-3AC/ASi-8A |
Power supply, 8 A, AS-i system voltage for masters,
sensors, actuators and modules, Three-phase AS-i power supply 380...480 V AC,
Integrated data decoupling, IP 20, Ambient temperature -25...70 °C, screw
terminals |
| AC1254 |
PSU-1AC/ASi-4A |
Power supply, 4 A, AS-i
system voltage for masters, sensors, actuators and modules, AS-i power supply
115/230 V AC, Integrated data decoupling, IP 20, Ambient temperature -25...70
°C, screw terminals |
| AC1256 |
PSU-1AC/ASi-2.8A |
Power supply, 2,8 A, AS-i system voltage for
masters, sensors, actuators and modules, AS-i power supply 115/230 V AC,
Integrated data decoupling, NEC Class II Power Source, IP 20, Ambient
temperature -25...70 °C, screw terminals |
| AC1257 |
PSU-24VDC/ASi-4A |
Power supply, 4 A, AS-i
system voltage for masters, sensors, actuators and modules, DC convertor 24 V
DC for AS-i system voltage, Integrated data decoupling, IP 20, Ambient
temperature -25...70 °C, screw terminals |
| AC1258 |
PSU-1AC/ASi-8A |
Power supply, 8 A, AS-i system voltage for masters,
sensors, actuators and modules, AS-i power supply 115/230 V AC, Integrated
data decoupling, IP 20, Ambient temperature -25...70 °C, screw terminals |
| AC2211 |
Earth Fault Monitoring
Device |
AS-i insulation monitor,
Use for earth fault monitoring in unearthed AS-i and 24 V DC systems (IT
system), Detection of asymmetric insulation faults, IP 20, Ambient
temperature -25...60 °C, terminals up to 0.75 mm² |
| AC2212 |
Insulation Monitoring Device |
AS-i insulation monitor, Use for insulation
monitoring in unearthed AS-i and 24 V DC systems (IT system), Detection of
symmetric and asymmetric insulation faults, IP 20, Ambient temperature
-25...60 °C, terminals up to 0.75 mm² |